Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38529760

RESUMO

OBJECTIVES: Occupational stress is a common complaint in nurses, who perceived more sense of effort-reward imbalance (ERI). Suboptimal health status (SHS) is a state between health and disease. However, the correlation between ERI and SHS is unclear. Therefore, the aim of this study was to examine the prevalence of SHS and ERI and evaluate the relationship between ERI and SHS in clinical nurses by a cross-sectional study. MATERIAL AND METHODS: The current cross-sectional study was conducted through an online survey at Dongping People's Hospital in China. A total of 633 completed surveys were received. Effort-reward imbalance was measured by subscales of the ERI questionnaire. SHS was measured by the Suboptimal Health Status Questionnaire - 25 (SHSQ-25). The relationship between ERI and SHS in nurses was subsequently assessed by Spearman's correlation coefficient and logistic regression model. RESULTS: The mean age of the optimal health status (OHS) group (M±SD 26.3±7.3 years) was younger than the SHS group (M±SD 30.3±6.9 years). The prevalence of SHS was 54.5% (345/633). Female nurses aged ≥30 years, a junior college or university graduate educational level, smokers, and nurses without regular exercise were at a higher risk of SHS. In Spearman's correlation analysis, ERI reflected by the effort-reward ratio was correlated with SHSQ-25 score (r = 0.662, p < 0.001). In logistic regression, ERI was strongly associated with SHS after potential confounding factors adjusting (OR 27.924, 95% CI 22.845-34.132). CONCLUSIONS: The prevalence of SHS was significantly high in clinical nurses. Administrators should pay more attention to health status of female nurses aged ≥30 years, with a junior college or bachelor's degree, smoking, and without regular exercise to reduce the SHS and ERI. Int J Occup Med Environ Health. 2024;37(2).

2.
Opt Lett ; 48(18): 4737-4740, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37707890

RESUMO

We demonstrate superluminescent diodes (SLDs) for visible light optical coherence tomography (OCT) of the human retina. SLDs are less costly than supercontinuum sources and have lower intrinsic excess noise, enabling imaging closer to the shot noise limit. While single SLDs are not broadband, they provide power concentrated at specific wavelengths relevant to retinal function. As a new, to the best of our knowledge, application, we image human macular pigments (MPs), which are thought to both aid vision and protect against advanced age-related macular degeneration. Using the unique depth-resolved capabilities of OCT, we localize MPs in depth to Henle's fibers beneath the foveal pit in the living human retina. Our approach reduces the cost of visible light OCT to nearly that of near-infrared (NIR) OCT while also providing information about clinically relevant MPs which cannot be measured in the NIR.


Assuntos
Pigmento Macular , Tomografia de Coerência Óptica , Humanos , Luz , Retina/diagnóstico por imagem
3.
J Glob Health ; 12: 04077, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36181723

RESUMO

Background: Suboptimal health status (SHS) is a reversible stage between health and illness that is characterized by health complaints, low energy, general weakness, and chronic fatigue. The Suboptimal Health Status Questionnaire-25 (SHSQ-25) has been validated in three major populations (African, Asian, and Caucasian) and is internationally recognized as a reliable and robust tool for health estimation in general populations. This study focused on the development of K-SHSQ-25, a Korean version of the SHSQ-25, from its English version. Methods: The SHSQ-25 was translated from English to Korean according to international guidelines set forth by the World Health Organization (WHO) for health instrument translation between different languages. A subsequent cross-sectional survey involved 460 healthy South Korean participants (aged 18-83 years; 65.4% females) to answer the 25 questions focusing on the health perspectives of 5 domains, 1) fatigue, 2) cardiovascular health, 3) digestive tract, 4) immune system and 5) mental health. The K-SHSQ-25 was further validated using tests for reliability, internal consistency, exploratory factor analysis (EFA), and confirmatory factor analysis (CFA). Results: The version of K-SHSQ-25 achieved linguistic, cultural, and conceptual equivalence to the English version. The intraclass correlation coefficient (ICC) of test-retest reliability for individual items ranged from 0.88 to 0.99. Reliability estimates based on internal consistency reached a Cronbach's α of 0.953; the Cronbach's α for each domain ranged from 0.76 to 0.94. Regarding construct validity, the EFA of the K-SHSQ-25 generally replicated the multidimensional structure (fatigue, cardiovascular, digestive, immune system, and mental health) and 25 questions. The CFA revealed that the root mean square error of approximation (RMSEA), goodness-of-fit index (GFI) and adjusted goodness of fit index (AGFI) were excellent (RMSEA = 0.069<0.08, GFI = 0.929>0.90, AGFI = 0.907>0.90). The five domains of the K-SHSQ-25 showed significant correlations with each other (r = 0.59-0.81, P<0.001). The cut-off point of K-SHSQ-25 for SHS was determined as an SHS score of 25. The prevalence of SHS in this study was 60.0% (276/460), with 47.8% (76/159) for males and 58.5% for females (176/301). Conclusions: Our results indicate that the Korean version of SHSQ-25, K-SHSQ-25, is a transcultural equivalent, robust, valid, and reliable assessment tool for evaluating SHS in the Korean-speaking population.


Assuntos
Comparação Transcultural , Idioma , Estudos Transversais , Feminino , Nível de Saúde , Humanos , Masculino , Medicina de Precisão , Reprodutibilidade dos Testes , República da Coreia , Inquéritos e Questionários
4.
J Biomed Opt ; 27(8)2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35996215

RESUMO

SIGNIFICANCE: Reflection Mueller matrix imaging is suitable for characterizing the microstructure of bulk specimens and probing dynamic processes in living animals, there are always demands for speed and accuracy for such applications to avoid possible artifacts and reveal a sample's intrinsic properties. AIM: To demonstrate a design of collinear reflection Mueller matrix fast imaging microscope based on dual division of focal plane (DoFP) polarimeters (DoFPs-CRMMM) which has high measurement speed and accuracy. APPROACH: In DoFPs-CRMMM, to improve the measurement speed, we applied the dual DoFP polarimeters design on the collinear reflection system for the first time to achieve fast imaging in about 2 s. To improve the measurement accuracy, we improved the double-pass eigenvalue calibration method (dp-ECM) by background light correction, and explored the optimization of the set of reference samples. RESULTS: DoFPs-CRMMM was applied to measure the standard polarization samples and monitor the tissue optical clearing process of an artificial layered bulk tissue. Results show that the system has satisfactory performance which can capture the variation of polarization properties during the dynamic process. CONCLUSIONS: We present the establishment and demo application of DoFPs-CRMMM. The measurement speed can be further accelerated for potential applications in monitoring dynamic processes or living biomedical systems.


Assuntos
Artefatos , Fenômenos Ópticos , Animais , Calibragem , Diagnóstico por Imagem
5.
Clin Case Rep ; 10(3): e05538, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35310307

RESUMO

To explore the clinical characteristics, diagnosis, and treatment of chronic lymphocytic leukemia with secondary pancytopenia. Here, a case of pancytopenia secondary to chronic lymphocytic leukemia is reported. Additionally, a review of relevant chronic lymphocytic leukemia literature was conducted to summarize its diagnosis, clinical characteristics, treatment history, and experience. After treatment with cyclosporine A, the patient's chronic lymphocytic leukemia continued to resolve, and hematopoiesis returned to normal. Cyclosporine A therapy resulted in improved patient outcomes. However, the mechanism by which cyclosporine A rebuilds the immune microenvironment and its antileukemia effect in the body remains to be studied.

6.
Opt Lett ; 46(16): 4009-4012, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-34388798

RESUMO

In this Letter, we report a study on the effects of spatial filtering for a transmission Mueller matrix imaging system. A spatial filter (SF) is placed on the back Fourier plane of the imaging lens in a dual-rotating-retarders Mueller matrix imaging system to select photons within a certain scattering angle. The system is then applied to three types of human cancerous tissues. When imaging with a small-aperture SF, some polarimetry basis parameters show sharp changes in contrast in the cancerous regions. Monte Carlo simulations using a simple sphere-cylinder scattering model also show that spatial filtering of the scattered photons provides extra information on the size and shape of the scattering particles. The results indicate that spatial filtering enhances the capability of polarization imaging as a powerful tool for biomedical diagnosis.


Assuntos
Neoplasias , Fótons , Diagnóstico por Imagem , Humanos , Microscopia de Polarização , Método de Monte Carlo
7.
Int J Mol Sci ; 22(11)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34073071

RESUMO

Gastric cancer is the fifth most common cancer and the third leading cause of cancer-related deaths worldwide. Histone deacetylase (HDAC) inhibitors are a new class of cytostatic agents available for the treatment of various cancers and diseases. Although numerous clinical and pre-clinical trials on the anticancer effects of panobinostat have been conducted, only a few reports have investigated its efficacy in gastric cancer. The present study aimed to investigate the effects of panobinostat in gastric cancer cells. Panobinostat significantly inhibited the cell viability and proliferation of the gastric cancer cell lines SNU484 and SNU638 in a dose-dependent manner; it reduced the colony-forming ability of these cells. Moreover, it induced apoptosis as indicated by increased protein levels of cleaved poly ADP-ribose polymerase and cleaved caspase-3. Panobinostat induced the G2/M cell cycle arrest in SNU484 and SNU638 cells and subsequently decreased the G2/M phase regulatory-associated protein expression of p-Wee1, Myt1, and Cdc2. Furthermore, panobinostat significantly inhibited the metastasis of SNU484 and SNU638 cells by regulating the expression of MMP-9 and E-cadherin. Further, it decreased the protein levels of p-Akt and forkhead box protein M1 (FOXM1). These effects were reversed by the Akt agonist SC79 and were accelerated by the Akt inhibitor LY2940002. Moreover, tumor growth in xenograft animal experiments was suppressed by panobinostat. These results indicated that panobinostat inhibits the proliferation, metastasis, and cell cycle progression of gastric cancer cells by promoting apoptosis and inactivating Akt/FOXM1 signaling. Cumulatively, our present study suggests that panobinostat is a potential drug for the treatment of gastric cancer.


Assuntos
Antineoplásicos , Apoptose/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Panobinostat , Transdução de Sinais/efeitos dos fármacos , Neoplasias Gástricas/tratamento farmacológico , Animais , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Feminino , Proteína Forkhead Box M1/metabolismo , Pontos de Checagem da Fase G2 do Ciclo Celular/efeitos dos fármacos , Humanos , Camundongos , Metástase Neoplásica/tratamento farmacológico , Panobinostat/farmacologia , Panobinostat/uso terapêutico , Proteínas Proto-Oncogênicas c-akt/metabolismo
8.
Biomed Opt Express ; 12(3): 1593-1608, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33796375

RESUMO

Digital pathology has shown great importance for diagnostic purposes in the digital age by integrating basic image features into multi-modality information. We quantify the degree of correlation between the multiple texture features from H&E images and polarization parameter sets derived from Mueller matrix images of the same sample to provide more microstructural information for assisting diagnosis. The experimental result shows the correlations between texture feature and polarization parameter via Pearson coefficients. Polarization parameters t1 , DL and the depolarization parameter Δ correlated with image texture features Tamura_Fcon and Tamura_Frgh, and can be used as powerful tools to quantitatively characterize cell nuclei related with tumor progression in breast pathological tissues. Polarization parameters δ and rL associated with the image texture feature Tamura_Flin have great potential for the quantitative characterization of proliferative fibers produced by inflammation. Furthermore, polarization parameters have the advantages of stable recognition in low resolution images. This work validates the associations between image texture features and polarization parameters and the merit of polarization imaging methods in low-resolution situations.

9.
Opt Lett ; 46(7): 1676-1679, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33793516

RESUMO

In this Letter, we report a dual division of focal plane (DoFP) polarimeters-based full Mueller matrix microscope (DoFPs-MMM) for fast polarization imaging. Both acquisition speed and measurement accuracy are improved compared with those of a Mueller matrix microscope based on dual rotating retarders. Then, the system is applied to probe the polarization properties of a red blood cells smear. The experimental results show that a DoFPs-MMM has the potential to be a powerful tool for probing dynamic processes in living cells in future studies.


Assuntos
Microscopia/instrumentação , Algoritmos , Desenho de Equipamento , Microscopia de Polarização
10.
Appl Opt ; 60(5): 1380-1386, 2021 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-33690582

RESUMO

Mueller matrix (MM) imaging has demonstrated its potential application in much research, especially in probing delicate and complex biomedical specimens. Qualities of MM images are important for further quantitative characterization. In this paper, we compare the performance and imaging qualities of three calibration methods. Air, waveplate and cell specimen are selected as standard samples for comparison. In addition, we also propose two general MM imaging quality indices that can be used as quantitative evaluations for MM imaging systems and calculation processes based on real samples. The numerical calibration method turns out to give the best accuracy and precision, as well as the best image qualities.


Assuntos
Microscopia de Polarização/métodos , Imagem Óptica/métodos , Ar , Calibragem/normas , Células HeLa , Humanos , Luz , Microscopia de Polarização/normas , Imagem Óptica/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...